Facts 

Name:POWERS FERRY RD over NANCY CREEK
Structure number:000000012104480
Location:IN N ATLANTA
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:44.9 ft. [13.7 m]
Total length:105.0 ft. [32.0 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:39.7 ft. [12.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1946
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2015 

Status:Open, no restriction [A]
Average daily traffic:6,460 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:41.6 tons [37.8 metric tons]
Inventory rating:24.8 tons [22.5 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:66.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$615,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
February 201566.4Functionally obsoleteSatisfactorySatisfactorySatisfactory6460
February 201356.3Functionally obsoleteSatisfactorySatisfactoryFair6460
February 201142.9Structurally deficientGoodGoodPoor6700
January 200918.2Structurally deficientGoodGoodPoor6700
January 200718.2Structurally deficientGoodGoodPoor6700
January 200518.3Structurally deficientGoodGoodPoor6440
February 200318.5Structurally deficientGoodGoodPoor6100
October 200014.8Structurally deficientGoodGoodPoor12600
June 199814.8Structurally deficientSatisfactoryGoodFair12600
January 199510.5Structurally deficientSatisfactoryGoodSerious12600
December 199210.5Structurally deficientSatisfactoryGoodSerious12600
January 199139.2Structurally deficientSatisfactoryGoodFair12600