Share:

ADAMS DRIVE over SOUTH UTOY CREEK

Map 

Coordinates:
+33.71553, -84.48643
33°42'56" N, 84°29'11" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:ADAMS DRIVE over SOUTH UTOY CREEK
Structure number:000000012151690
Location:IN SOUTHWEST ATLANTA
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:10.8 ft. [3.3 m]
Total length:46.9 ft. [14.3 m]
Skew angle:24°
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

2010 Inspection 

Status:Bridge closed to all traffic [K]
Average daily traffic:1,900 [as of 2007]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Bridge closed. Corrective action may put back in light service. [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Evaluation:Structurally deficient [1]
Sufficiency rating:40.1

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:1,810 [as of 1998]
Truck traffic:3% of total traffic
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:47.5 tons [43.2 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:92.2

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:1,640 [as of 1990]
Truck traffic:3% of total traffic
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:47.5 tons [43.2 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:92.2