Facts 

Name:HOLLYWOOD ROAD over PROCTOR CREEK
Structure number:000000012152940
Location:IN ATLANTA
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:107.0 ft. [32.6 m]
Total length:264.1 ft. [80.5 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:64.3 ft. [19.6 m]
Skew angle:
Owner:City or Municipal Highway Agency [04]
Year built:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2014 

Status:Open, no restriction [A]
Average daily traffic:2,890 [as of 2011]
Truck traffic:1% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge with "unknown" foundation that has not been evaluated for scour. [U]
Operating rating:49.5 tons [45.0 metric tons]
Inventory rating:29.7 tons [27.0 metric tons]
Sufficiency rating:89.3
Estimated cost of work:$1,547,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201489.3Not deficientGoodVery GoodVery Good2890
November 201289.3Not deficientGoodVery GoodVery Good2890
December 201087.5Not deficientVery GoodVery GoodVery Good11370
December 200887.5Not deficientVery GoodVery GoodVery Good11370
November 200691.7Not deficientVery GoodVery GoodVery Good11370
December 200491.7Not deficientVery GoodVery GoodVery Good11370
April 200278.3Not deficientVery GoodVery GoodVery Good11370