Share:

FM over CANOE CREEK

Map 

Coordinates:
+43.36111, -91.64722
43°21'40" N, 91°38'50" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FM over CANOE CREEK
Structure number:000000000348340
Location:099072604
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:75.1 ft. [22.9 m]
Total length:191.0 ft. [58.2 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:21.3 ft. [6.5 m]
Owner:County Highway Agency [02]
Year built:1935
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: April 2015 

Status:Open, no restriction [A]
Average daily traffic:180 [as of 2013]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:21.1 tons [19.2 metric tons]
Inventory rating:11.8 tons [10.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:43.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201543.8Functionally obsoleteSatisfactorySatisfactorySatisfactory180
March 201343.8Functionally obsoleteSatisfactorySatisfactorySatisfactory180
March 201143.9Functionally obsoleteSatisfactorySatisfactorySatisfactory120
March 200948.1Not deficientSatisfactorySatisfactorySatisfactory180
April 200748.3Not deficientSatisfactorySatisfactorySatisfactory180
June 200548.3Not deficientSatisfactorySatisfactorySatisfactory180
December 200248.4Not deficientSatisfactorySatisfactorySatisfactory120
May 200148.4Not deficientSatisfactorySatisfactorySatisfactory120
March 199948.2Not deficientSatisfactorySatisfactorySatisfactory130
April 199748.1Not deficientSatisfactorySatisfactorySatisfactory150
November 199448.1Not deficientSatisfactorySatisfactorySatisfactory150
May 199356.0Not deficientSatisfactorySatisfactorySatisfactory240
May 199156.0Not deficientSatisfactorySatisfactorySatisfactory240