Facts 

Name:MADISON ST over I- 90,94 JFK
Structure number:000016205326314
Location:0.4 M N I-290
Purpose:Carries highway overpass over highway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:102.0 ft. [31.1 m]
Total length:286.4 ft. [87.3 m]
Roadway width between curbs:47.9 ft. [14.6 m]
Deck width edge-to-edge:77.4 ft. [23.6 m]
Vertical clearance below bridge:15.7 ft. [4.8 m]
Owner:State Highway Agency [01]
Year built:1956
Year reconstructed:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:9,900 [as of 2006]
Truck traffic:12% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:68.3 tons [62.1 metric tons]
Inventory rating:36.6 tons [33.3 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:79.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:10,000 [as of 1994]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:68.3 tons [62.1 metric tons]
Inventory rating:36.6 tons [33.3 metric tons]
Sufficiency rating:79.0

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,000 [as of 1986]
Deck condition:Poor [4 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:68.3 tons [62.1 metric tons]
Inventory rating:36.6 tons [33.3 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:65.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]