RANDOLPH ST over UNION STA TRKS
Map
Coordinates:
+41.88447, -87.6339941°53'04" N, 87°38'02" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | RANDOLPH ST over UNION STA TRKS |
| Structure number: | 000016633916922 |
| Location: | 150N.& 430W.TO 500W |
| Purpose: | Carries highway over railroad |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 85.0 ft. [25.9 m] |
| Total length: | 212.9 ft. [64.9 m] |
| Roadway width between curbs: | 47.9 ft. [14.6 m] |
| Deck width edge-to-edge: | 80.1 ft. [24.4 m] |
| Vertical clearance below bridge: | 17.1 ft. [5.2 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1985 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Latex Concrete or similar additive [3] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 6,300 [as of 2006] |
| Truck traffic: | 11% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 77.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $2,699,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 18,300 [as of 1997] |
| Truck traffic: | 3% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 77.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $2,699,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 92.0 |