I-90 SKYWAY over 86TH ST
Map
Coordinates:
+41.73876, -87.5704141°44'20" N, 87°34'13" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I-90 SKYWAY over 86TH ST |
| Structure number: | 000016640704328 |
| Location: | 0.2 M SE 85TH P7C |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Tolls: | Yes, on toll road [2] |
| Length of largest span: | 68.9 ft. [21.0 m] |
| Total length: | 71.9 ft. [21.9 m] |
| Roadway width between curbs: | 99.7 ft. [30.4 m] |
| Deck width edge-to-edge: | 106.0 ft. [32.3 m] |
| Vertical clearance below bridge: | 14.4 ft. [4.4 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1958 |
| Year reconstructed: | 2007 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Latex Concrete or similar additive [3] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 23,950 [as of 2009] |
| Truck traffic: | 11% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 85.7 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,100 [as of 1995] |
| Truck traffic: | 16% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 48.5 tons [44.1 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 89.2 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,100 [as of 1990] |
| Truck traffic: | 13% of total traffic |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 75.3 |
| Recommended work: | Widening of existing bridge with deck rehabilitation or replacement. [34] |
| Estimated cost of work: | $525,000 |