Share:

I-90 SKYWAY EB over 87TH ST

Map 

Coordinates:
+41.73719, -87.56861
41°44'14" N, 87°34'07" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-90 SKYWAY EB over 87TH ST
Structure number:000016640804357
Location:0.1 M W S CHGO AVE P
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Tolls:Yes, on toll road [2]
Length of largest span:124.7 ft. [38.0 m]
Total length:128.3 ft. [39.1 m]
Roadway width between curbs:47.2 ft. [14.4 m]
Deck width edge-to-edge:50.5 ft. [15.4 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Skew angle:39°
Owner:City or Municipal Highway Agency [04]
Year built:1958
Year reconstructed:2006
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:23,950 [as of 2009]
Truck traffic:11% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:81.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,550 [as of 1995]
Truck traffic:16% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:77.6

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,550 [as of 1990]
Truck traffic:13% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:75.5