Share:

PUMPKIN RUN Rd over BLACK River

Map 

Coordinates:
+38.22611, -87.81778
38°13'34" N, 87°49'04" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:PUMPKIN RUN Rd over BLACK River
Structure number:6500193
Location:0 Int of 1285N 550E
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:42.0 ft. [12.8 m]
Total length:107.0 ft. [32.6 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:24.3 ft. [7.4 m]
Owner:County Highway Agency [02]
Year built:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Precast Panels [2]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:125 [as of 2002]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:89.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:125 [as of 1998]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:92.0

1992 Inspection 

Status:Posted for load [P]
Average daily traffic:100 [as of 1985]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Scour calculation/evaluation has not been made. [6]
Operating rating:13.9 tons [12.6 metric tons]
Inventory rating:9.9 tons [9.0 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:43.6
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$1,000