Share:

CENTRAL over EAST BRANCH GYPSUM CREEK

Map 

Coordinates:
+37.69385, -97.23298
37°41'38" N, 97°13'59" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:CENTRAL over EAST BRANCH GYPSUM CREEK
Structure number:430400876400120
Location:CENTRAL AT LINDEN DRIVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:9.8 ft. [3.0 m]
Total length:30.8 ft. [9.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1958
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2015 

Status:Posted for load [P]
Average daily traffic:14,500 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:31.9 tons [29.0 metric tons]
Inventory rating:18.9 tons [17.2 metric tons]
Sufficiency rating:61.4
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$42,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
November 201561.4Not deficient---14500
October 201354.1Functionally obsolete---14500
September 201154.1Functionally obsolete---14500
November 200954.1Functionally obsolete---14500
July 200754.1Functionally obsolete---14500
November 200252.4Functionally obsolete---14163
February 200052.4Functionally obsolete---14163
March 199752.9Functionally obsolete---11219
January 199554.1Not deficient---11000
April 199377.6Functionally obsolete---14671
May 199177.8Functionally obsolete---11936