Facts 

Name:29TH ST. N over CROOKED CREEK
Structure number:5304008700029W2
Location:0.1 MI. E OF OLIVER
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:16.1 ft. [4.9 m]
Total length:49.9 ft. [15.2 m]
Roadway width between curbs:41.3 ft. [12.6 m]
Deck width edge-to-edge:59.4 ft. [18.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: December 2015 

Status:Open, no restriction [A]
Average daily traffic:8,500 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:76.9 tons [69.9 metric tons]
Inventory rating:45.9 tons [41.7 metric tons]
Sufficiency rating:80.5

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
December 201580.5Not deficient---8500
October 201379.5Not deficient---8500
October 201180.5Not deficient---8500
November 200978.4Functionally obsolete---8500
July 200778.4Functionally obsolete---8500
November 200279.4Not deficient---5282
February 200079.4Not deficient---5282