Share:

Hoover over TRIB TO WVCFLOODWAY

Map 

Coordinates:
+37.66500, -97.40833
37°39'54" N, 97°24'30" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:Hoover over TRIB TO WVCFLOODWAY
Structure number:53040087000HH10
Location:HARRY AND HOOVER
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:20.7 ft. [6.3 m]
Roadway width between curbs:48.6 ft. [14.8 m]
Deck width edge-to-edge:84.0 ft. [25.6 m]
Owner:City or Municipal Highway Agency [04]
Year built:1977
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2015 

Status:Open, no restriction [A]
Average daily traffic:3,000 [as of 2006]
Truck traffic:2% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.0 tons [31.8 metric tons]
Inventory rating:21.0 tons [19.1 metric tons]
Sufficiency rating:80.9

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
December 201580.9Not deficient---3000
October 201380.9Not deficient---3000
September 201163.7Functionally obsolete---3000
October 200982.9Not deficient---3000
July 200782.9Not deficient---3000
October 200376.4Functionally obsolete---5355