Share:

SENECA over TRIB TO WVCFLOODWAY

Map 

Coordinates:
+37.58000, -97.35167
37°34'48" N, 97°21'06" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.

Facts 

Name:SENECA over TRIB TO WVCFLOODWAY
Structure number:5304008700SSD50
Location:SENECA AND 61ST ST
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:9.8 ft. [3.0 m]
Total length:21.0 ft. [6.4 m]
Roadway width between curbs:44.9 ft. [13.7 m]
Deck width edge-to-edge:77.1 ft. [23.5 m]
Owner:City or Municipal Highway Agency [04]
Year built:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:7,200 [as of 2006]
Truck traffic:2% of total traffic
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:54.9 tons [49.9 metric tons]
Inventory rating:32.9 tons [29.9 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:78.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$3,000