I-35 HWY, SB over CAMBRIDGE CIRCLE
Map
Coordinates:
+39.07472, -94.6213939°04'29" N, 94°37'17" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | I-35 HWY, SB over CAMBRIDGE CIRCLE |
| Structure number: | 999903501053161 |
| Location: | 2.4 MI N US-69/I-35 JCT |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 52.5 ft. [16.0 m] |
| Total length: | 185.7 ft. [56.6 m] |
| Roadway width between curbs: | 56.1 ft. [17.1 m] |
| Deck width edge-to-edge: | 58.7 ft. [17.9 m] |
| Vertical clearance below bridge: | 16.7 ft. [5.1 m] |
| Skew angle: | 16° |
| Owner: | State Highway Agency [01] |
| Year built: | 2007 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Number of main spans: | 4 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Low slump Concrete [4] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 41,050 [as of 2009] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 98.8 tons [89.8 metric tons] |
| Inventory rating: | 92.8 tons [84.4 metric tons] |
| Sufficiency rating: | 96.1 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |
| Estimated cost of work: | $359,000 |