Share:

KY-339 over MASSAC CREEK

Map 

Coordinates:
+37.01472, -88.69361
37°00'53" N, 88°41'37" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:KY-339 over MASSAC CREEK
Structure number:073B00058N
Old structure number:073*0339*B0058 (from 1992 edition)
Location:1.5 MI S.W. OF JCT US 45
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:40.0 ft. [12.2 m]
Total length:86.0 ft. [26.2 m]
Roadway width between curbs:34.5 ft. [10.5 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2015 

Status:Posted for load [P]
Average daily traffic:2,387 [as of 2012]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Poor [4 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Operating rating:15.0 tons [13.6 metric tons]
Inventory rating:15.0 tons [13.6 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:42.4
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201542.4Structurally deficientSatisfactorySatisfactoryPoor2387
March 201442.5Structurally deficientSatisfactorySatisfactoryPoor2264
March 201342.8Structurally deficientSatisfactorySatisfactoryPoor2070
March 201242.7Structurally deficientSatisfactorySatisfactoryPoor2110
March 201142.6Structurally deficientSatisfactorySatisfactoryPoor2170
February 201057.7Not deficientSatisfactorySatisfactoryFair2050
February 200898.1Not deficientSatisfactorySatisfactorySatisfactory1880
September 200599.3Not deficientSatisfactorySatisfactorySatisfactory1473
September 200382.8Not deficientSatisfactorySatisfactoryFair3981
September 200182.8Not deficientSatisfactorySatisfactoryFair3981
September 199982.8Not deficientSatisfactorySatisfactoryFair3981
September 199794.1Not deficientSatisfactorySatisfactorySatisfactory3981
September 199593.3Not deficientFairSatisfactorySatisfactory3620
September 199394.4Not deficientSatisfactorySatisfactorySatisfactory3620
September 199194.4Not deficientSatisfactorySatisfactorySatisfactory3620