CITYST over I 10
Map
Coordinates:
+29.99914, -90.1871929°59'57" N, 90°11'14" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | CITYST over I 10 |
| Structure number: | 022604501505732 |
| Location: | 3.7 MI EAST OF LA 49 |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 83.0 ft. [25.3 m] |
| Total length: | 1402.0 ft. [427.3 m] |
| Roadway width between curbs: | 25.9 ft. [7.9 m] |
| Deck width edge-to-edge: | 33.5 ft. [10.2 m] |
| Vertical clearance below bridge: | 18.0 ft. [5.5 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1967 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 21 |
| Main spans material: | Prestressed concrete [5] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 26,850 [as of 2009] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 96.0 tons [87.3 metric tons] |
| Inventory rating: | 49.5 tons [45.0 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 75.7 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $5,467,000 |