LA0046 over SISTER STREET
Map
Coordinates:
+29.96357, -90.0264029°57'49" N, 90°01'35" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | LA0046 over SISTER STREET |
| Structure number: | 023600460202341 |
| Location: | 2.34 MI SOUTH OF LA 39 |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 17.1 ft. [5.2 m] |
| Total length: | 51.8 ft. [15.8 m] |
| Roadway width between curbs: | 47.9 ft. [14.6 m] |
| Deck width edge-to-edge: | 60.0 ft. [18.3 m] |
| Vertical clearance below bridge: | 13.5 ft. [4.1 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1960 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | M 13.5 / H 15 [2] |
| Number of main spans: | 3 |
| Main spans material: | Concrete [1] |
| Main spans design: | Slab [01] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 15,500 [as of 2009] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Poor [4 out of 9] |
| Substructure condition: | Poor [4 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 42.6 tons [38.7 metric tons] |
| Inventory rating: | 25.7 tons [23.4 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 28.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $351,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 18,949 [as of 1998] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Operating rating: | 96.0 tons [87.3 metric tons] |
| Inventory rating: | 59.4 tons [54.0 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 54.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $351,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 43,104 [as of 1991] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Operating rating: | 96.0 tons [87.3 metric tons] |
| Inventory rating: | 59.4 tons [54.0 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 50.0 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $351,000 |