Share:

I0610 over ON RAMP I-610E.

Map 

Coordinates:
+29.99546, -90.11569
29°59'44" N, 90°06'56" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I0610 over ON RAMP I-610E.
Structure number:023604503400485
Location:.5 MI EAST OF I-10
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:44.9 ft. [13.7 m]
Total length:390.1 ft. [118.9 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:27.6 ft. [8.4 m]
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:4,630 [as of 2009]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:61.4 tons [55.8 metric tons]
Inventory rating:36.6 tons [33.3 metric tons]
Sufficiency rating:92.5

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:7,510 [as of 1998]
Truck traffic:6% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Operating rating:44.6 tons [40.5 metric tons]
Inventory rating:31.7 tons [28.8 metric tons]
Sufficiency rating:91.0
Recommended work:Other structural work, including hydraulic replacements. [38]

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:8,534 [as of 1991]
Truck traffic:6% of total traffic
Deck condition:Poor [4 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:25.7 tons [23.4 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:81.4
Recommended work:Other structural work, including hydraulic replacements. [38]