I0310 over RAMP"C"FROM I 310 SB
Map
Coordinates:
+29.93234, -90.3801129°55'56" N, 90°22'48" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I0310 over RAMP"C"FROM I 310 SB |
| Structure number: | 024504503800362 |
| Location: | .36 MI SOUTH OF LA 18 |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 92.9 ft. [28.3 m] |
| Total length: | 1290.1 ft. [393.2 m] |
| Roadway width between curbs: | 38.1 ft. [11.6 m] |
| Deck width edge-to-edge: | 41.3 ft. [12.6 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1979 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 16 |
| Main spans material: | Prestressed concrete continuous [6] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 31,000 [as of 2009] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 59.4 tons [54.0 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 93.6 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 27,716 [as of 1998] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Operating rating: | 61.4 tons [55.8 metric tons] |
| Inventory rating: | 36.6 tons [33.3 metric tons] |
| Sufficiency rating: | 87.8 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 9,712 [as of 1991] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Operating rating: | 43.6 tons [39.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 95.5 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |