CITYST over I-20
Map
Coordinates:
+32.45044, -93.8655532°27'02" N, 93°51'56" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | CITYST over I-20 |
| Structure number: | 040904510110601 |
| Location: | 1.9 MI EAST OF LA 526 |
| Purpose: | Carries highway over highway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 85.0 ft. [25.9 m] |
| Total length: | 272.0 ft. [82.9 m] |
| Roadway width between curbs: | 84.0 ft. [25.6 m] |
| Deck width edge-to-edge: | 86.6 ft. [26.4 m] |
| Vertical clearance below bridge: | 16.1 ft. [4.9 m] |
| Owner: | State Highway Agency [01] |
| Year built: | 1977 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Prestressed concrete [5] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 36,400 [as of 2009] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 94.1 tons [85.5 metric tons] |
| Inventory rating: | 49.5 tons [45.0 metric tons] |
| Sufficiency rating: | 98.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 29,358 [as of 1997] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Operating rating: | 44.6 tons [40.5 metric tons] |
| Inventory rating: | 31.7 tons [28.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 77.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $2,040,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 23,028 [as of 1991] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Operating rating: | 44.6 tons [40.5 metric tons] |
| Inventory rating: | 31.7 tons [28.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 77.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $2,040,000 |