Share:

CITY STREET over PIERRE BAYOU TRY.

Map 

Coordinates:
+32.47540, -93.73306
32°28'31" N, 93°43'59" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:CITY STREET over PIERRE BAYOU TRY.
Structure number:040932285934391
Location:0.1 MI W OF ALEXANDER AVE
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:9.8 ft. [3.0 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:62.0 ft. [18.9 m]
Owner:City or Municipal Highway Agency [04]
Year built:1988
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: April 2015 

Status:Open, no restriction [A]
Average daily traffic:1,381 [as of 1988]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:43.6 tons [39.6 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:95.1

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201595.1Not deficient---1381
April 201395.1Not deficient---1381
April 201195.1Not deficient---1381
March 200995.1Not deficient---1381
March 200795.1Not deficient---1381
March 200595.1Not deficient---1381
March 200395.1Not deficient---1381
March 200195.1Not deficient---1381
February 199995.1Not deficient---1381
January 199795.1Not deficient---1381
January 199595.1Not deficient---1381
March 199395.1Not deficient---1381
March 199195.1Not deficient---1381