Share:

LOCAL ROAD over STONER AVE, LINE AVE

Map 

Coordinates:
+32.49998, -93.74604
32°29'60" N, 93°44'46" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:LOCAL ROAD over STONER AVE, LINE AVE
Structure number:040932300934481
Location:1.3 MI. WEST OF LA 1
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:69.9 ft. [21.3 m]
Total length:380.9 ft. [116.1 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:49.5 ft. [15.1 m]
Vertical clearance below bridge:15.4 ft. [4.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: March 2015 

Status:Posted for load [P]
Average daily traffic:10,120 [as of 1979]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:25.7 tons [23.4 metric tons]
Inventory rating:14.9 tons [13.5 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:35.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,683,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201535.9Structurally deficientFairFairFair10120
March 201335.9Structurally deficientFairFairFair10120
March 201135.9Structurally deficientFairFairFair10120
April 200935.9Functionally obsoleteFairFairFair10120
April 200735.9Functionally obsoleteFairFairFair10120
March 200535.9Functionally obsoleteFairFairFair10120
March 200335.9Functionally obsoleteFairFairFair10120
February 200135.9Functionally obsoleteFairFairFair10120
March 199935.9Functionally obsoleteFairFairFair10120
February 199735.9Functionally obsoleteFairFairFair10120
February 199536.6Functionally obsoleteFairFairFair10120
March 199336.6Functionally obsoleteFairFairFair10120
April 199137.7Functionally obsoleteSatisfactoryFairSatisfactory10120