LOCAL ROAD over PINE HILL RD,MCCAIN CREE
Map
Coordinates:
+32.58389, -93.8260132°35'02" N, 93°49'34" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | LOCAL ROAD over PINE HILL RD,MCCAIN CREE |
| Structure number: | 040932350934961 |
| Location: | 1.6 MI. WEST OF LA 1 |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 39.0 ft. [11.9 m] |
| Total length: | 39.0 ft. [11.9 m] |
| Owner: | County Highway Agency [02] |
| Year built: | 1978 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Culvert [19] |
| Deck type: | Not applicable [N] |
2010 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 3,000 [as of 1979] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 24.8 tons [22.5 metric tons] |
| Sufficiency rating: | 88.9 |
2000 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 3,000 [as of 1979] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 24.8 tons [22.5 metric tons] |
| Sufficiency rating: | 88.9 |
1992 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 3,000 [as of 1979] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Operating rating: | 32.7 tons [29.7 metric tons] |
| Inventory rating: | 24.8 tons [22.5 metric tons] |
| Sufficiency rating: | 88.8 |