LOCAL ROAD over FARMERS L & C CO. CANAL
Map
Coordinates:
+30.22667, -93.2150030°13'36" N, 93°12'54" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | LOCAL ROAD over FARMERS L & C CO. CANAL |
| Structure number: | 071030136931291 |
| Location: | 0.02 MI. S. OF INT. |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 15.1 ft. [4.6 m] |
| Total length: | 29.9 ft. [9.1 m] |
| Roadway width between curbs: | 24.0 ft. [7.3 m] |
| Deck width edge-to-edge: | 24.9 ft. [7.6 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1960 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 2 |
| Main spans material: | Concrete [1] |
| Main spans design: | Culvert [19] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1971] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 27.7 tons [25.2 metric tons] |
| Sufficiency rating: | 79.7 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1971] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Culvert condition: | Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 27.7 tons [25.2 metric tons] |
| Sufficiency rating: | 79.7 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 500 [as of 1971] |
| Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
| Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 27.7 tons [25.2 metric tons] |
| Sufficiency rating: | 78.7 |