LOCAL ROAD over CREEK
Map
Coordinates:
+31.76594, -92.3298331°45'57" N, 92°19'47" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | LOCAL ROAD over CREEK |
| Structure number: | 583031460921981 |
| Location: | P3031460921981 |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Rural) [09] |
| Length of largest span: | 15.1 ft. [4.6 m] |
| Total length: | 29.9 ft. [9.1 m] |
| Roadway width between curbs: | 14.8 ft. [4.5 m] |
| Deck width edge-to-edge: | 15.7 ft. [4.8 m] |
| Skew angle: | 8° |
| Owner: | County Highway Agency [02] |
| Year built: | 1955 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | M 9 / H 10 [1] |
| Number of main spans: | 2 |
| Main spans material: | Wood or timber [7] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Wood or Timber [8] |
| Wearing surface: | Other [9] |
2010 Inspection
| Status: | Posted for load [P] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 15.8 tons [14.4 metric tons] |
| Inventory rating: | 10.9 tons [9.9 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 29.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $138,000 |
2000 Inspection
| Status: | Posted for load [P] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Poor [4 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 19.8 tons [18.0 metric tons] |
| Inventory rating: | 14.9 tons [13.5 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 25.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $138,000 |
1992 Inspection
| Status: | Posted for load [P] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Poor [4 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
| Operating rating: | 17.8 tons [16.2 metric tons] |
| Inventory rating: | 12.9 tons [11.7 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 22.3 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $138,000 |