Facts 

Name:CITYST over I-110
Structure number:611704509201031
Location:61174509201031
Purpose:Carries highway over highway
Route classification:Local (Urban) [19]
Length of largest span:68.9 ft. [21.0 m]
Total length:173.9 ft. [53.0 m]
Roadway width between curbs:28.2 ft. [8.6 m]
Deck width edge-to-edge:40.4 ft. [12.3 m]
Vertical clearance below bridge:15.7 ft. [4.8 m]
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:48,750 [as of 2009]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:63.4 tons [57.6 metric tons]
Inventory rating:37.6 tons [34.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:57.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$795,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:30,152 [as of 1997]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Operating rating:54.5 tons [49.5 metric tons]
Inventory rating:38.6 tons [35.1 metric tons]
Sufficiency rating:77.0

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:36,728 [as of 1991]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Operating rating:51.5 tons [46.8 metric tons]
Inventory rating:37.6 tons [34.2 metric tons]
Sufficiency rating:79.0