Share:

HWY EMBKT WB OFF over HWY EMBKNT EB&WB ON RP

Map 

Coordinates:
+42.36167, -71.07167
42°21'42" N, 71°04'18" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:HWY EMBKT WB OFF over HWY EMBKNT EB&WB ON RP
Structure number:B162574FMDOTNBI
Location:CHARLES CIRCLE STORROW D
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:109.9 ft. [33.5 m]
Total length:496.1 ft. [151.2 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Vertical clearance below bridge:11.2 ft. [3.4 m]
Skew angle:16°
Owner:State Highway Agency [01]
Year built:1951
Year reconstructed:1996
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:7
Main spans material:Steel [3]
Main spans design:Girder and floorbeam system [03]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2015 

Status:Posted for other load-capacity restriction [R]
Average daily traffic:9,700 [as of 2013]
Truck traffic:1% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Scour condition:Bridge not over waterway. [N]
Operating rating:23.5 tons [21.4 metric tons]
Inventory rating:14.3 tons [13.0 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:43.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$5,380,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
January 201543.7Functionally obsoleteSatisfactorySatisfactorySatisfactory9700
January 20134.0Functionally obsoleteSatisfactorySatisfactorySatisfactory9700
January 20114.0Functionally obsoleteSatisfactorySatisfactoryFair9700
January 20094.0Functionally obsoleteSatisfactorySatisfactoryFair9700