Share:

I 90 WB RAMP OFF over RR CSX

Map 

Coordinates:
+42.35806, -71.12056
42°21'29" N, 71°07'14" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:I 90 WB RAMP OFF over RR CSX
Structure number:B163584RWDOTNBI
Location:.1 MI S. CHARLES RV S111
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Tolls:Yes, on toll road [2]
Length of largest span:85.0 ft. [25.9 m]
Total length:315.3 ft. [96.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:47.9 ft. [14.6 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Owner:State Highway Agency [01]
Year built:1965
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2015 

Status:Open, no restriction [A]
Average daily traffic:16,500 [as of 2015]
Truck traffic:7% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:55.4 tons [50.4 metric tons]
Inventory rating:33.2 tons [30.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:55.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$7,973,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
January 201555.2Functionally obsoleteFairFairSatisfactory16500
January 201354.8Functionally obsoleteFairFairSatisfactory19915
January 201179.0Functionally obsoleteFairFairSatisfactory111
October 200879.0Functionally obsoleteFairFairSatisfactory111