FULTON AVENUE over I-170
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | FULTON AVENUE over I-170 |
| Structure number: | 200000BC1211010 |
| Location: | 0.1 MI S OF FRANKLIN ST |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 77.1 ft. [23.5 m] |
| Total length: | 222.1 ft. [67.7 m] |
| Roadway width between curbs: | 64.0 ft. [19.5 m] |
| Deck width edge-to-edge: | 89.9 ft. [27.4 m] |
| Vertical clearance below bridge: | 33.1 ft. [10.1 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1975 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Box Beam or girders - Single or Spread [06] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 5,600 [as of 2007] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 91.1 tons [82.8 metric tons] |
| Inventory rating: | 40.6 tons [36.9 metric tons] |
| Sufficiency rating: | 91.5 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $41,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 4,919 [as of 1994] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 91.1 tons [82.8 metric tons] |
| Inventory rating: | 40.6 tons [36.9 metric tons] |
| Sufficiency rating: | 91.5 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $41,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 4,919 [as of 1988] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 91.1 tons [82.8 metric tons] |
| Inventory rating: | 40.6 tons [36.9 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 91.6 |