CALHOUN STREET over I-170
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | CALHOUN STREET over I-170 |
| Structure number: | 200000BC1503010 |
| Location: | 0.1 MI N OF SARATOGA ST |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 77.1 ft. [23.5 m] |
| Total length: | 179.1 ft. [54.6 m] |
| Roadway width between curbs: | 51.8 ft. [15.8 m] |
| Deck width edge-to-edge: | 69.9 ft. [21.3 m] |
| Vertical clearance below bridge: | 15.7 ft. [4.8 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1977 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Concrete continuous [2] |
| Main spans design: | Box Beam or girders - Single or Spread [06] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,840 [as of 2007] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 94.1 tons [85.5 metric tons] |
| Inventory rating: | 43.6 tons [39.6 metric tons] |
| Sufficiency rating: | 84.6 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $17,000 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,425 [as of 1994] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 94.1 tons [85.5 metric tons] |
| Inventory rating: | 43.6 tons [39.6 metric tons] |
| Sufficiency rating: | 91.4 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $34,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,425 [as of 1969] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 94.1 tons [85.5 metric tons] |
| Inventory rating: | 43.6 tons [39.6 metric tons] |
| Sufficiency rating: | 92.9 |