I-83 over PUMPING STATION
Map
Coordinates:
+39.32000, -76.6300039°19'12" N, 76°37'48" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I-83 over PUMPING STATION |
| Structure number: | 200000BC3108010 |
| Location: | 0.5 MI N OF NORTH AVENUE |
| Route classification: | Other Principal Arterial (Urban) [14] |
| Length of largest span: | 86.9 ft. [26.5 m] |
| Total length: | 90.9 ft. [27.7 m] |
| Roadway width between curbs: | 49.2 ft. [15.0 m] |
| Deck width edge-to-edge: | 77.4 ft. [23.6 m] |
| Vertical clearance below bridge: | 19.0 ft. [5.8 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1959 |
| Year reconstructed: | 1988 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 26,180 [as of 2007] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 65.3 tons [59.4 metric tons] |
| Inventory rating: | 31.7 tons [28.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 71.9 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $29,000 |
2000 Inspection
| Status: | Open, posting recommended but not legally implemented [B] |
| Average daily traffic: | 20,499 [as of 1994] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 65.3 tons [59.4 metric tons] |
| Inventory rating: | 31.7 tons [28.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 72.9 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $14,000 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 20,499 [as of 1988] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 57.4 tons [52.2 metric tons] |
| Inventory rating: | 31.7 tons [28.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 72.7 |