Share:

SPOOKS HILL ROAD over COOPERS RUN

Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:SPOOKS HILL ROAD over COOPERS RUN
Structure number:200000BC6523010
Location:0.8 MI E BECKLEYSVILLE RD
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:29.9 ft. [9.1 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:City or Municipal Highway Agency [04]
Year built:1933
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:95 [as of 2007]
Deck condition:Poor [4 out of 9]
Superstructure condition:Serious [3 out of 9]
Substructure condition:Poor [4 out of 9]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:77.2 tons [70.2 metric tons]
Inventory rating:46.5 tons [42.3 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:52.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$200,000

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:75 [as of 1994]
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Operating rating:77.2 tons [70.2 metric tons]
Inventory rating:46.5 tons [42.3 metric tons]
Sufficiency rating:87.0
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$24,000

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:75 [as of 1981]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge not over waterway. [N]
Operating rating:77.2 tons [70.2 metric tons]
Inventory rating:46.5 tons [42.3 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:70.0