FREDERICK AVENUE over AMTRAK
Map
Coordinates:
+39.28500, -76.6716739°17'06" N, 76°40'18" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | FREDERICK AVENUE over AMTRAK |
| Structure number: | 200000BC9013010 |
| Location: | AT JCT WITH HILTON ST. |
| Purpose: | Carries highway and pedestrian walkway over railroad |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 92.9 ft. [28.3 m] |
| Total length: | 100.1 ft. [30.5 m] |
| Roadway width between curbs: | 46.3 ft. [14.1 m] |
| Deck width edge-to-edge: | 66.9 ft. [20.4 m] |
| Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
| Skew angle: | 13° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1925 |
| Year reconstructed: | 2001 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Girder and floorbeam system [03] |
| Deck type: | Concrete Cast-in-Place [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 2,102 [as of 2007] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 74.7 |
| Recommended work: | Other structural work, including hydraulic replacements. [38] |
| Estimated cost of work: | $6,000 |
2000 Inspection
| Status: | Bridge closed to all traffic [K] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 29.7 tons [27.0 metric tons] |
| Evaluation: | Not applicable [N] |
| Sufficiency rating: | 85.9 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,844 [as of 1988] |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Scour calculation/evaluation has not been made. [6] |
| Operating rating: | 49.5 tons [45.0 metric tons] |
| Inventory rating: | 29.7 tons [27.0 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 65.7 |