Share:

I-94 WB over I-94 RAMP FROM M-10

Map 

Coordinates:
+42.35948, -83.07626
42°21'34" N, 83°04'35" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-94 WB over I-94 RAMP FROM M-10
Structure number:82182023000S280
Location:IN DETROIT,OVER RAMP HE,S
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:78.7 ft. [24.0 m]
Total length:195.9 ft. [59.7 m]
Roadway width between curbs:50.2 ft. [15.3 m]
Deck width edge-to-edge:53.8 ft. [16.4 m]
Vertical clearance below bridge:15.1 ft. [4.6 m]
Skew angle:57°
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Bridge is on the National Register of Historic Places [1]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:70,585 [as of 2007]
Truck traffic:9% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:84.0 tons [76.4 metric tons]
Inventory rating:40.0 tons [36.4 metric tons]
Sufficiency rating:87.1

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:63,000 [as of 1995]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:84.0 tons [76.4 metric tons]
Inventory rating:40.0 tons [36.4 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:85.6

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:54,800 [as of 1982]
Truck traffic:10% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Inventory rating:39.6 tons [36.0 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:87.6