M-10 RAMP over M-8 EB DAVISON
Map
Coordinates:
+42.39834, -83.1097342°23'54" N, 83°06'35" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | M-10 RAMP over M-8 EB DAVISON |
| Structure number: | 82182112000S140 |
| Location: | IN DETROIT |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 123.0 ft. [37.5 m] |
| Total length: | 301.9 ft. [92.0 m] |
| Roadway width between curbs: | 25.3 ft. [7.7 m] |
| Deck width edge-to-edge: | 28.5 ft. [8.7 m] |
| Vertical clearance below bridge: | 14.8 ft. [4.5 m] |
| Skew angle: | 60° |
| Owner: | State Highway Agency [01] |
| Year built: | 1957 |
| Year reconstructed: | 1996 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Steel [3] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,840 [as of 1982] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 77.1 tons [70.1 metric tons] |
| Inventory rating: | 46.3 tons [42.1 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 92.2 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,840 [as of 1982] |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 77.1 tons [70.1 metric tons] |
| Inventory rating: | 46.3 tons [42.1 metric tons] |
| Sufficiency rating: | 87.1 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 17,840 [as of 1982] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 34.7 tons [31.5 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 79.1 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |
| Estimated cost of work: | $37,000 |