UNDERWOOD AVE over I-96
Map
Coordinates:
+42.36516, -83.1333642°21'55" N, 83°08'00" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | UNDERWOOD AVE over I-96 |
| Structure number: | 82182123000S320 |
| Location: | IN DETROIT |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 86.9 ft. [26.5 m] |
| Total length: | 174.2 ft. [53.1 m] |
| Roadway width between curbs: | 29.5 ft. [9.0 m] |
| Deck width edge-to-edge: | 42.0 ft. [12.8 m] |
| Vertical clearance below bridge: | 14.4 ft. [4.4 m] |
| Skew angle: | 2° |
| Owner: | State Highway Agency [01] |
| Year built: | 1972 |
| Year reconstructed: | 2009 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 2 |
| Main spans material: | Steel [3] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 1,700 [as of 2008] |
| Truck traffic: | 1% of total traffic |
| Deck condition: | Poor [4 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 56.0 tons [50.9 metric tons] |
| Sufficiency rating: | 83.7 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 3,300 [as of 1988] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 56.0 tons [50.9 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 75.4 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 3,000 [as of 1974] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Poor [4 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 55.4 tons [50.4 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 51.0 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |
| Estimated cost of work: | $203,000 |