EB DAVISON (M-8) over I-96 WYOMING EXIT RAMP
Map
Coordinates:
+42.38562, -83.1591642°23'08" N, 83°09'33" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | EB DAVISON (M-8) over I-96 WYOMING EXIT RAMP |
| Structure number: | 82182123000S510 |
| Location: | IN DETROIT |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 122.1 ft. [37.2 m] |
| Total length: | 122.1 ft. [37.2 m] |
| Roadway width between curbs: | 28.9 ft. [8.8 m] |
| Deck width edge-to-edge: | 35.1 ft. [10.7 m] |
| Vertical clearance below bridge: | 14.8 ft. [4.5 m] |
| Skew angle: | 63° |
| Owner: | State Highway Agency [01] |
| Year built: | 1971 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Main span material: | Steel [3] |
| Main span design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 77,500 [as of 1995] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Poor [4 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 99.2 tons [90.2 metric tons] |
| Inventory rating: | 59.6 tons [54.2 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 50.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 77,500 [as of 1995] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 99.2 tons [90.2 metric tons] |
| Inventory rating: | 59.6 tons [54.2 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 63.0 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 4,360 [as of 1982] |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 55.4 tons [50.4 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 78.0 |