Share:

I-94 EB ENT RAMP over I-75 RAMP TO I-94

Map 

Coordinates:
+42.36854, -83.05792
42°22'07" N, 83°03'29" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:I-94 EB ENT RAMP over I-75 RAMP TO I-94
Structure number:82182251000S210
Location:IN DETROIT
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:78.7 ft. [24.0 m]
Total length:171.9 ft. [52.4 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:26.9 ft. [8.2 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Skew angle:53°
Owner:State Highway Agency [01]
Year built:1961
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:6,740 [as of 1982]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.8 tons [75.3 metric tons]
Inventory rating:78.9 tons [71.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:96.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:6,740 [as of 1982]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.8 tons [75.3 metric tons]
Inventory rating:78.9 tons [71.7 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:91.0

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:6,740 [as of 1982]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Inventory rating:58.4 tons [53.1 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:94.0