Facts 

Name:I-75 over CONRAIL RR
Structure number:82182252000R080
Location:IN DETROIT
Purpose:Carries highway over railroad
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:60.7 ft. [18.5 m]
Total length:220.2 ft. [67.1 m]
Roadway width between curbs:166.7 ft. [50.8 m]
Deck width edge-to-edge:173.6 ft. [52.9 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:99°
Owner:State Highway Agency [01]
Year built:1969
Year reconstructed:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:174,074 [as of 2007]
Truck traffic:7% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Scour condition:Bridge not over waterway. [N]
Operating rating:95.0 tons [86.4 metric tons]
Inventory rating:49.0 tons [44.5 metric tons]
Sufficiency rating:81.0

2000 Inspection 

Status:Open, no restriction [A]
Average daily traffic:211,000 [as of 1995]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Poor [4 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Operating rating:95.0 tons [86.4 metric tons]
Inventory rating:49.0 tons [44.5 metric tons]
Evaluation:Structurally deficient [1]
Sufficiency rating:58.0
Recommended work:Bridge deck replacement with only incidental widening. [37]

1992 Inspection 

Status:Open, no restriction [A]
Average daily traffic:112,600 [as of 1982]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge not over waterway. [N]
Inventory rating:48.5 tons [44.1 metric tons]
Sufficiency rating:85.0