I-75 over MCNICHOLS RD
Map
Coordinates:
+42.41822, -83.0880542°25'06" N, 83°05'17" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | I-75 over MCNICHOLS RD |
| Structure number: | 82182252000S220 |
| Location: | IN DETROIT OVER MCNICHOLS |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Interstate (Urban) [11] |
| Length of largest span: | 82.0 ft. [25.0 m] |
| Total length: | 224.7 ft. [68.5 m] |
| Roadway width between curbs: | 142.7 ft. [43.5 m] |
| Deck width edge-to-edge: | 149.3 ft. [45.5 m] |
| Vertical clearance below bridge: | 15.1 ft. [4.6 m] |
| Skew angle: | 29° |
| Owner: | State Highway Agency [01] |
| Year built: | 1969 |
| Year reconstructed: | 2003 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18+Mod / HS 20+Mod [6] |
| Number of main spans: | 4 |
| Main spans material: | Prestressed concrete [5] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 174,074 [as of 2007] |
| Truck traffic: | 7% of total traffic |
| Deck condition: | Very Good [8 out of 9] |
| Superstructure condition: | Very Good [8 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 36.0 tons [32.7 metric tons] |
| Inventory rating: | 36.0 tons [32.7 metric tons] |
| Sufficiency rating: | 92.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 211,000 [as of 1995] |
| Truck traffic: | 6% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Serious [3 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 102.3 tons [93.0 metric tons] |
| Inventory rating: | 61.4 tons [55.8 metric tons] |
| Evaluation: | Structurally deficient [1] |
| Sufficiency rating: | 52.0 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 112,600 [as of 1982] |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Pier/abutment protection: | Navigation protection not required [1] |
| Scour condition: | Bridge not over waterway. [N] |
| Inventory rating: | 47.5 tons [43.2 metric tons] |
| Sufficiency rating: | 81.0 |
| Recommended work: | Bridge deck replacement with only incidental widening. [37] |