Portland Ave over I 35W & I 94 WB
Map
Coordinates:
+44.96551, -93.2676544°57'56" N, 93°16'04" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | Portland Ave over I 35W & I 94 WB |
| Structure number: | 27851 |
| Location: | 0.6 Mi West of Jct TH 55 |
| Purpose: | Carries highway and pedestrian walkway over highway |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 133.9 ft. [40.8 m] |
| Total length: | 378.6 ft. [115.4 m] |
| Roadway width between curbs: | 56.4 ft. [17.2 m] |
| Deck width edge-to-edge: | 74.5 ft. [22.7 m] |
| Vertical clearance below bridge: | 15.1 ft. [4.6 m] |
| Skew angle: | 15° |
| Owner: | State Highway Agency [01] |
| Year built: | 1967 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 4 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Low slump Concrete [4] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 13,300 [as of 2005] |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 79.0 tons [71.8 metric tons] |
| Inventory rating: | 47.4 tons [43.1 metric tons] |
| Sufficiency rating: | 93.7 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 118,000 [as of 1996] |
| Truck traffic: | 4% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 78.4 tons [71.3 metric tons] |
| Inventory rating: | 47.1 tons [42.8 metric tons] |
| Evaluation: | Not applicable [N] |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 13,800 [as of 1990] |
| Truck traffic: | 1% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 35.6 tons [32.4 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 82.7 |