Share:

ARSENAL over RVR DES PERES, BNSF RR

Map 

Coordinates:
+38.60956, -90.30830
38°36'34" N, 90°18'30" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.

Facts 

Name:ARSENAL over RVR DES PERES, BNSF RR
Structure number:12426
Old structure number:0100.021 115 (from 1992 edition)
Location:S 26 T 45 N R 6 E
Purpose:Carries highway over railroad and waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:136.2 ft. [41.5 m]
Total length:679.2 ft. [207.0 m]
Roadway width between curbs:51.8 ft. [15.8 m]
Deck width edge-to-edge:67.9 ft. [20.7 m]
Owner:City or Municipal Highway Agency [04]
Year built:1995
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

2010 Inspection 

Status:Open, no restriction [A]
Average daily traffic:18,950 [as of 2009]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Operating rating:59.4 tons [54.0 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:74.4

2000 Inspection 

Status:Posted for load [P]
Average daily traffic:18,650 [as of 1998]
Truck traffic:5% of total traffic
Deck condition:Excellent [9 out of 9]
Superstructure condition:Excellent [9 out of 9]
Substructure condition:Excellent [9 out of 9]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.4 tons [54.0 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:73.4