Share:

SUBLETTE AVE over RVR DES PERES

Map 

Coordinates:
+38.62192, -90.28045
38°37'19" N, 90°16'50" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:SUBLETTE AVE over RVR DES PERES
Structure number:12434
Location:S. OF MANCHESTER
Purpose:Carries highway over waterway
Route classification:Local (Urban) [19]
Length of largest span:55.1 ft. [16.8 m]
Total length:110.6 ft. [33.7 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Skew angle:12°
Owner:City or Municipal Highway Agency [04]
Year built:1987
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2016 

Status:Posted for load [P]
Average daily traffic:5,700 [as of 2014]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:62.4 tons [56.7 metric tons]
Inventory rating:37.6 tons [34.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:78.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$552,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
March 201678.7Functionally obsoleteGoodGoodVery Good5700
March 201478.7Functionally obsoleteVery GoodVery GoodVery Good5700
March 201278.7Functionally obsoleteVery GoodVery GoodVery Good5700
May 201078.7Functionally obsoleteVery GoodVery GoodVery Good5700
April 200878.7Functionally obsoleteVery GoodVery GoodVery Good5700
May 200678.7Functionally obsoleteVery GoodVery GoodVery Good5700
March 200478.7Functionally obsoleteVery GoodVery GoodVery Good5700
April 200278.7Functionally obsoleteVery GoodVery GoodVery Good5700
May 200078.7Functionally obsoleteVery GoodVery GoodVery Good5700