VANDEVENTER AVE over BNSF RR
Map
Coordinates:
+38.62260, -90.2553338°37'21" N, 90°15'19" W
Source: National Bridge Inventory (2010 edition)
Information not verified. Use at your own risk.
Facts
| Name: | VANDEVENTER AVE over BNSF RR |
| Structure number: | 12820 |
| Location: | S 20 T 45 N R 7 E |
| Purpose: | Carries highway over railroad |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 67.9 ft. [20.7 m] |
| Total length: | 195.9 ft. [59.7 m] |
| Roadway width between curbs: | 47.9 ft. [14.6 m] |
| Deck width edge-to-edge: | 59.4 ft. [18.1 m] |
| Skew angle: | 47° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1984 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 13,530 [as of 2009] |
| Truck traffic: | 5% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Good [7 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 62.4 tons [56.7 metric tons] |
| Inventory rating: | 41.6 tons [37.8 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 77.2 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $1,407,000 |