WOODSWETHER RD over UP RR
Map
Coordinates:
+39.10989, -94.5897839°06'36" N, 94°35'23" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | WOODSWETHER RD over UP RR |
| Structure number: | 25396 |
| Old structure number: | S029B45 048 (from 1992 edition) |
| Location: | S 30 T 50 N R 33 W |
| Purpose: | Carries highway over railroad |
| Route classification: | Collector (Urban) [17] |
| Length of largest span: | 147.0 ft. [44.8 m] |
| Total length: | 500.0 ft. [152.4 m] |
| Roadway width between curbs: | 29.9 ft. [9.1 m] |
| Deck width edge-to-edge: | 35.1 ft. [10.7 m] |
| Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
| Skew angle: | 99° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1951 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | M 18 / H 20 [4] |
| Number of main spans: | 6 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 3,300 [as of 2009] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Fair [5 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 53.5 tons [48.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 64.5 |
2000 Inspection
| Status: | Posted for load [P] |
| Average daily traffic: | 2,718 [as of 1998] |
| Truck traffic: | 20% of total traffic |
| Deck condition: | Fair [5 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Fair [5 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 53.5 tons [48.6 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 64.8 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $945,000 |