Share:

BLUE RIDGE CUT OFF over ROUND GROVE CR

Map 

Coordinates:
+39.03638, -94.47645
39°02'11" N, 94°28'35" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:BLUE RIDGE CUT OFF over ROUND GROVE CR
Structure number:25454
Old structure number:S085B21 048 (from 1992 edition)
Location:S 29 T 49 N R 32 W
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:9.8 ft. [3.0 m]
Total length:21.0 ft. [6.4 m]
Roadway width between curbs:68.6 ft. [20.9 m]
Deck width edge-to-edge:128.0 ft. [39.0 m]
Skew angle:10°
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2014 

Status:Open, no restriction [A]
Average daily traffic:12,012 [as of 2014]
Truck traffic:3% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:46.5 tons [42.3 metric tons]
Inventory rating:27.7 tons [25.2 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:72.3
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$127,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
April 201472.3Functionally obsolete---12012
March 201272.3Functionally obsolete---12012
April 201071.6Functionally obsolete---15700
March 200871.6Functionally obsolete---15700
February 200671.6Functionally obsolete---15700
March 200471.6Functionally obsolete---15700
June 200271.0Functionally obsolete---18611
July 200071.0Functionally obsolete---18611
May 199870.7Functionally obsolete---20000
June 199670.7Functionally obsolete---20000
October 199470.4Functionally obsolete---20000
November 199277.1Functionally obsolete---20000