US 169 N over IS 435
Map
Coordinates:
+39.30951, -94.5843139°18'34" N, 94°35'04" W
Source: National Bridge Inventory (1992, 2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | US 169 N over IS 435 |
| Structure number: | 2819 |
| Old structure number: | A3334 3 (from 1992 edition) |
| Location: | S 22 T 52 N R 33 W |
| Purpose: | Carries highway over highway |
| Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
| Length of largest span: | 129.9 ft. [39.6 m] |
| Total length: | 294.0 ft. [89.6 m] |
| Roadway width between curbs: | 36.1 ft. [11.0 m] |
| Deck width edge-to-edge: | 39.4 ft. [12.0 m] |
| Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
| Skew angle: | 11° |
| Owner: | State Highway Agency [01] |
| Year built: | 1981 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 2 |
| Main spans material: | Steel continuous [4] |
| Main spans design: | Stringer/Multi-beam or girder [02] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 4,530 [as of 2009] |
| Truck traffic: | 21% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 60.5 tons [55.0 metric tons] |
| Inventory rating: | 42.9 tons [39.0 metric tons] |
| Sufficiency rating: | 97.8 |
2000 Inspection
| Average daily traffic: | 14,000 [as of 1996] |
| Truck traffic: | 10% of total traffic |
| Evaluation: | Not applicable [N] |
| Sufficiency rating: | 94.7 |
1992 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 5,619 [as of 1991] |
| Truck traffic: | 10% of total traffic |
| Deck condition: | Good [7 out of 9] |
| Superstructure condition: | Good [7 out of 9] |
| Substructure condition: | Very Good [8 out of 9] |
| Scour condition: | Bridge not over waterway. [N] |
| Operating rating: | 69.3 tons [63.0 metric tons] |
| Inventory rating: | 42.6 tons [38.7 metric tons] |
| Sufficiency rating: | 97.6 |
| Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
| Estimated cost of work: | $863,000 |