Share:

MICHIGAN AVE S over BRUSH CR

Map 

Coordinates:
+39.04152, -94.55955
39°02'29" N, 94°33'34" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:MICHIGAN AVE S over BRUSH CR
Structure number:4040
Location:S 28 T 49 N R 33 W
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Local (Urban) [19]
Length of largest span:127.0 ft. [38.7 m]
Total length:557.1 ft. [169.8 m]
Roadway width between curbs:28.9 ft. [8.8 m]
Deck width edge-to-edge:38.4 ft. [11.7 m]
Skew angle:44°
Owner:State Highway Agency [01]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: October 2015 

Status:Open, no restriction [A]
Average daily traffic:8,569 [as of 2014]
Truck traffic:10% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:69.3 tons [63.0 metric tons]
Inventory rating:41.6 tons [37.8 metric tons]
Evaluation:Functionally obsolete [2]
Sufficiency rating:77.5
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$1,848,000

Previous Inspections 

DateSuff. ratingEvaluationDeckSuper.Sub.ADT
October 201577.5Functionally obsoleteGoodVery GoodVery Good8569
October 201377.5Functionally obsoleteGoodVery GoodExcellent8569
October 201178.0Functionally obsoleteGoodVery GoodExcellent5500
October 200978.0Functionally obsoleteVery GoodVery GoodExcellent5500
January 200878.0Functionally obsoleteVery GoodVery GoodExcellent5500
November 200578.0Not deficientVery GoodVery GoodExcellent5500
November 200378.0Not deficientVery GoodVery GoodExcellent5500
September 200178.7Not deficientExcellentExcellentExcellent13153