W. MITCHELL AVE over SMALL DITCH
Map
Coordinates:
+32.33616, -90.1877532°20'10" N, 90°11'16" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | W. MITCHELL AVE over SMALL DITCH |
| Structure number: | SA2500000000240 |
| Location: | SEC 27 T 6N R 1E |
| Purpose: | Carries highway over waterway |
| Route classification: | Minor Arterial (Urban) [16] |
| Length of largest span: | 7.9 ft. [2.4 m] |
| Total length: | 29.9 ft. [9.1 m] |
| Roadway width between curbs: | 44.0 ft. [13.4 m] |
| Deck width edge-to-edge: | 59.7 ft. [18.2 m] |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 2009 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 3 |
| Main spans material: | Concrete [1] |
| Main spans design: | Culvert [19] |
| Deck type: | Concrete Cast-in-Place [1] |
| Wearing surface: | Bituminous [6] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 2,400 [as of 2007] |
| Truck traffic: | 8% of total traffic |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Culvert condition: | No deficiencies [9] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 80.7 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 5,080 [as of 1997] |
| Truck traffic: | 8% of total traffic |
| Deck condition: | Satisfactory [6 out of 9] |
| Superstructure condition: | Satisfactory [6 out of 9] |
| Substructure condition: | Satisfactory [6 out of 9] |
| Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
| Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
| Operating rating: | 24.8 tons [22.5 metric tons] |
| Inventory rating: | 18.8 tons [17.1 metric tons] |
| Evaluation: | Functionally obsolete [2] |
| Sufficiency rating: | 70.8 |
| Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
| Estimated cost of work: | $43,000 |