BELL ST over TRIB TOWN CREEK
Map
Coordinates:
+32.31311, -90.1924232°18'47" N, 90°11'33" W
Source: National Bridge Inventory (2000, 2010 editions)
Information not verified. Use at your own risk.
Facts
| Name: | BELL ST over TRIB TOWN CREEK |
| Structure number: | SA2500000000262 |
| Location: | SEC 34 T 6N R 1E |
| Purpose: | Carries highway over waterway |
| Route classification: | Local (Urban) [19] |
| Length of largest span: | 12.1 ft. [3.7 m] |
| Total length: | 25.9 ft. [7.9 m] |
| Skew angle: | 30° |
| Owner: | City or Municipal Highway Agency [04] |
| Year built: | 1953 |
| Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
| Design load: | MS 18 / HS 20 [5] |
| Number of main spans: | 2 |
| Main spans material: | Concrete [1] |
| Main spans design: | Culvert [19] |
| Deck type: | Not applicable [N] |
2010 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 140 [as of 2007] |
| Truck traffic: | 8% of total traffic |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 100.0 |
2000 Inspection
| Status: | Open, no restriction [A] |
| Average daily traffic: | 400 [as of 1997] |
| Truck traffic: | 8% of total traffic |
| Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
| Culvert condition: | No noticeable or noteworthy deficiencies which affect the condition of the culvert. Insignificant scrape marks caused by drift. [8] |
| Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
| Operating rating: | 47.5 tons [43.2 metric tons] |
| Inventory rating: | 35.6 tons [32.4 metric tons] |
| Sufficiency rating: | 100.0 |